HTTP-A16A-N2        
  Nominal Port Size:
1/2 - 2 inches ,
Clamp-on
Specifications:
Transducer Pkg: HTTS Small Pipe
Power Supply: 115 VAC
Notes: Requires HTTS Transducer
   Line Size: 1/2 to 2 inches
Output 1: 4-20 mA
Output 2: Data Logger
HTTP-A16A-NH        
  Nominal Port Size:
2 inches ,
Clamp-on
Specifications:
Transducer Pkg: HTTH High Temp
Power Supply: 115 VAC
Notes: None
   Line Size: 2 inches and higher
Output 1: 4-20 mA
Output 2: Data Logger
HTTP-A16A-NN        
  Nominal Port Size:
2 inches ,
Clamp-on
Specifications:
Transducer Pkg: HTTN Standard
Power Supply: 115 VAC
Notes: None
   Line Size: 2 inches and higher
Output 1: 4-20 mA
Output 2: Data Logger
HTTP-A1NA-N2        
  Nominal Port Size:
1/2 - 2 inches ,
Clamp-on
Specifications:
Transducer Pkg: HTTS Small Pipe
Power Supply: 115 VAC
Notes: Requires HTTS Transducer
   Line Size: 1/2 to 2 inches
Output 1: 4-20 mA
Output 2: None
HTTP-A1NA-NH        
  Nominal Port Size:
2 inches ,
Clamp-on
Specifications:
Transducer Pkg: HTTH High Temp
Power Supply: 115 VAC
Notes: None
   Line Size: 2 inches and higher
Output 1: 4-20 mA
Output 2: None
HTTP-A1NA-NN        
  Nominal Port Size:
2 inches ,
Clamp-on
Specifications:
Transducer Pkg: HTTN Standard
Power Supply: 115 VAC
Notes: None
   Line Size: 2 inches and higher
Output 1: 4-20 mA
Output 2: None
HTTP-B16A-N2        
  Nominal Port Size:
1/2 - 2 inches ,
Clamp-on
Specifications:
Transducer Pkg: HTTS Small Pipe
Power Supply: 230 VAC (2 round terminals)
Notes: Requires HTTS Transducer
   Line Size: 1/2 to 2 inches
Output 1: 4-20 mA
Output 2: Data Logger
HTTP-B16A-NH        
  Nominal Port Size:
2 inches ,
Clamp-on
Specifications:
Transducer Pkg: HTTH High Temp
Power Supply: 230 VAC (2 round terminals)
Notes: None
   Line Size: 2 inches and higher
Output 1: 4-20 mA
Output 2: Data Logger
HTTP-B16A-NN        
  Nominal Port Size:
2 inches ,
Clamp-on
Specifications:
Transducer Pkg: HTTN Standard
Power Supply: 230 VAC (2 round terminals)
Notes: None
   Line Size: 2 inches and higher
Output 1: 4-20 mA
Output 2: Data Logger
HTTP-B1NA-N2        
  Nominal Port Size:
1/2 - 2 inches ,
Clamp-on
Specifications:
Transducer Pkg: HTTS Small Pipe
Power Supply: 230 VAC (2 round terminals)
Notes: Requires HTTS Transducer
   Line Size: 1/2 to 2 inches
Output 1: 4-20 mA
Output 2: None


ISO 9001:2008 certified, click to view certificateClick to view Statement on European Union RoHS Compliance
© 2013 Racine Federated Inc., all rights reserved.