HTTF Integral Model
The Hedland HTTF Ultrasonic Transit Time Flow Meters clamp onto the outside of existing piping and do not contact the internal liquid. This advanced product provides instantaneous rate and accumulated flows along with 4-20 mA and pulse outputs. These non-invasive, compact meters were designed to replace mechanical flow meters in applications where liquid conditions tend to damage or impede mechanical flow meter operation.
|
| Typical Applications: |
|
Chemical distribution |
|
Machine tool/process cooling |
|
Well water |
|
Remediation
|
| Features include: |
|
Non-invasive meter clamps onto the outside of existing piping |
|
Easy, low cost installation |
|
No moving parts for maintenance free operation |
|
Pipe sizes 1/2 inch through 2 inches
for larger pipe sizes see the HTTF Remote Model
|
|
Available with or without a local display |
|
Direct interface to data collection systems |
|
Bi-directional flow capability to measure forward total, reverse total and net total |
|
ULTRALINK™ Windows®-based software utility allows configuration, calibration and troubleshooting |
|
 |
HTTF Integral Model |
 |
HTTF Remote Model |
 |
HTTP Portable Model |
 |
ULTRALINK Software |
 |
Accessories |
 |
 |



Downloads
|
 |
HTTF Remote Model
The Hedland HTTF Ultrasonic Transit Time Flow Meters clamp onto the outside of existing piping and do not contact the internal liquid. This advanced product provides instantaneous rate and accumulated flows along with 4-20 mA and pulse outputs. These non-invasive, compact meters were designed to replace mechanical flow meters in applications where liquid conditions tend to damage or impede mechanical flow meter operation.
|
| Typical Applications: |
|
Chemical distribution |
|
Machine tool/process cooling |
|
Well water |
|
Remediation
|
| Features include: |
|
Non-invasive meter clamps onto the outside of existing piping |
|
Easy, low cost installation |
|
No moving parts for maintenance free operation |
|
Pipe sizes:
- Small pipe transducers; 1/2 inch up to 2 inches
- Large pipe transducers; 2 inch through 100 inches
|
|
Available with or without a local display |
|
Direct interface to data collection systems |
|
Bi-directional flow capability to measure forward total, reverse total and net total |
|
ULTRALINK™ Windows®-based software utility allows configuration, calibration and troubleshooting |
|
 |
HTTF Integral Model |
 |
HTTF Remote Model |
 |
HTTP Portable Model |
 |
ULTRALINK Software |
 |
Accessories |
 |
 |



Downloads
|
 |
HTTP Portable Model
The Hedland Series HTTP
Portable Ultrasonic Transit Time Flow Meters clamp onto the outside of pipe and
do not contact the internal liquid. This advanced product provides instantaneous rate and
accumulated flows along with 4-20 mA output. A removable 200,000 event Data Logger module
is optional and features an integral DB-9 connection that plugs directly into a PC serial
port for very fast 57.6K data uploads. ULTRALINK™, a Windows®-based
software utility, is a complete meter configuration, calibration and troubleshooting tool.
Communication with the HTTP meter is achieved via a PC serial communications port and
infrared serial adapter allowing the user the convenience of no interconnection wires.
|
| Features include: |
|
Non-invasive meter clamps onto the outside of
piping |
|
Easy, low cost installation |
|
No moving parts for maintenance free operation |
|
Pipe sizes from 1/2 inch and higher |
|
Bi-directional flow capability to measure forward total, reverse
total and net total |
|
Optional, removable 200,000 event Data Logger |
|
ULTRALINK™ Windows®-based software utility
allows configuration, calibration and troubleshooting |
|
All HTTP systems include the following packaged in a
compartmentalized and padded carrying case: - HTTP meter - Ultrasonic transducer
set - Transducer interconnection cable, 20 ft. - 1 Tube of acoustic couplant - Mounting
hardware - AC power converter - Auto-style 12 VDC converter - Infrared adapter - 4-20
mA Interface cable - Operations manual |
|
 |
HTTF Integral Model |
 |
HTTF Remote Model |
 |
HTTP Portable Model |
 |
ULTRALINK Software |
 |
Accessories |
 |
 |


Software Downloads
|
 |
ULTRALINKTM Software
ULTRALINK is a Windows® 98/2000/XP compatible software utility tool that provides complete meter configuration, calibration and troubleshooting for the Hedland HTTF and HTTP Transit Time Flow Meters.
Communication is achieved via a PC serial communications port and the HTTF serial cable or the HTTP infrared serial adapter.
|
| Features and benefits of the software include: |
|
Quick access to all configuration parameters with pop-up windows and pull down menus |
|
Assistance in selection of proper position and mounting locations of system transducers |
|
Selection of units of measure and measuring range |
|
Powerful in-field multi-point calibration routine |
|
Display of error codes and log of reset functions |
|
Storage of meter configurations to a file that can be archived or used to configure additional meters |
To download a FREE copy of the ULTRALINK software, click on the link under Software Downloads and follow the instructions. A CD version of the software can also be purchased for a minimal charge by contacting Hedland Sales at 800-433-5263 and requesting part number HTTP-086. |
|
| Windows is a registered trademark of Microsoft Corp. |
|
 |
HTTF Integral Model |
 |
HTTF Remote Model |
 |
HTTP Portable Model |
 |
ULTRALINK Software |
 |
Accessories |
 |
 |



|
 |
Accessories
Hedland offers a complete line of product accessories and spare parts for the ultrasonic flow meters including transducers, acoustic couplant, mounting hardware, power converters, and cables. |
|
 |
|
|
 |
|
|
 |